Automated Evaluation of Pulmonary Trunk and Arteries Dimensions
Purpose | An automated algorithm, based on the reference values, should identify patients showing dilatation or reduction of pulmonary arteries caliber |
Tag(s) |
|
Panel | Cardiac Panel |
Define-AI ID | 19040037 |
Originator | Giuseppe Muscogiuri |
Lead | Giuseppe Muscogiuri |
Panel Chair | Carlo De Cecco |
Panel Reviewers | Cardiac Panel |
License | Creative Commons 4.0 |
Status | Public Commenting |
RadElement Set | RDES81 |
Clinical Implementation
Value PropositionIdentification of pulmonary artery and pulmonary trunk dimensions could be fundamental in patients with congenital heart disease or acquired disease.
Patients with acquired or congenital heart disease can show pulmonary trunk, and pulmonary artery enlargement.
Narrative(s)
Patients with suspicious or known heart disease undergo cardiac CT. AI algorithm identifies the caliber of pulmonary arteries. After evaluation of indexed dimensions, the algorithm automatically inserts the dimensions of pulmonary arteries in the report, specifying if the vessels are enlarged or reduced.
Workflow Description
CCTA acquisition are sent automatically to PACS or post-processing software. Images will be rapidly evaluated by the software and the results appended to report.
Considerations for Dataset Development
Procedures | CT |
CT acquisition | CT images will be acquired with and without contrast (eg calcium score acquisition). |
Sex at Birth | Male, Female |
Age | [0,90] |
Cardiac phase acquisition | Images will be carefully evaluated based on different cardiac phase acquisition. |
Breath Artifacts | absent, present |
Technical Specifications
Inputs
DICOM Study
Procedure | CT, Chest |
Views | Axial images |
Data Type | DICOM |
Modality | CT images |
Body Region | Chest |
Anatomic Focus | Pulmonary arteries |
Primary Outputs
Dimensions of Pulmonary arteries
RadElement ID | RDE449 |
Definition | Measure pulmonary artery dimensions |
Data Type | Numerical |
Value Set | N/A |
Units | mm |
Pulmonary arteries evaluation
RadElement ID | RDE452 |
Definition | Compare pulmonary artery measurements to reference values to determine status |
Data Type | Categorical |
Value Set | 0- Normal 1-Enlarged 2-Reduced 3-Unknown |
Units | N/A |
Secondary Outputs
Dimensions of segmental and lobar pulmonary artery dimensions.
RadElement ID | RDE450 |
Definition | Defines dimensions of lobar and segmental pulmonary arteries |
Data Type | Numerical |
Value Set | N/A |
Units | Millimeters |
Future Development Ideas
-
Evaluation of pulmonary arteries dimensions would be implemented in the future for the detection of chronic pulmonary embolism.
Related Datasets